    In the last years safety in LV electrical installations has taken an increasingly dominant role.

    Also from a normative point of view, the panorama has become more complete and a large number of users consider safety in the first place among the necessary requirements for their own plant.

    [ABB]

    В последние годы значительно возросло внимание к безопасности низковольтных электроустановок.

    Более широко вопросы безопасности рассмотрены и в нормативной документации. Большое число потребителей среди требований, выдвигаемых к своим электроустановкам, на первое место ставят вопросы безопасности.

    [Перевод Интент]

    Тематики

    EN

    Русско-английский словарь нормативно-технической терминологии > безопасность низковольтной электроустановки

  • 2 НКУ распределения и управления

    1. switchgear/controlgear
    2. switchgear and controlgear
    3. switchboard
    4. PSC-assembly
    5. power switchgear and controlgear assembly
    6. panel
    7. LV switchgear assembly
    8. LV switchgear and controlgear assembly
    9. low-voltage switchgear and controlgear assembly
    10. low voltage switchgear and controlgear assembly
    11. low voltage switchboard
    12. low voltage controlgear and assembly
    13. electrical switchboard
    14. assembly

     

    низковольтное устройство распределения и управления (НКУ)
    Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
    [ ГОСТ Р МЭК 61439-1-2012]

    низковольтное устройство распределения и управления

    Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
    Примечания
    1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
    2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
    3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    EN

    power switchgear and controlgear assembly (PSC-assembly)
    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    [IEC 61439-2, ed. 1.0 (2009-01)]

    low-voltage switchgear and controlgear assembly
    combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
    [IEC 61892-3, ed. 2.0 (2007-11)]

    switchgear and controlgear
    a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
    [IEV number 441-11-01]

    switchgear and controlgear

    electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
    NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
    [IEV number 826-16-03 ]

    switchboard
    A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
    [ McGraw-Hill Dictionary of Architecture & Construction]

    switchboard
    One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
    [ The American Heritage Dictionary of the English Language]

    FR

    ensemble d'appareillage de puissance (ensemble PSC)
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    [IEC 61439-2, ed. 1.0 (2009-01)]

    appareillage, m
    matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
    NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
    [IEV number 826-16-03 ]

    appareillage
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
    [IEV number 441-11-01]


    A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
    Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
    The types of switchboards, classified by basic features of construction, are as follows:
    1. Live-front vertical panels
    2. Dead-front boards
    3. Safety enclosed boards( metal-clad)


    [American electricians’ handbook]

    Параллельные тексты EN-RU

    The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.

    Its definition, design and installation are based on precise rules; there is no place for improvisation.

    The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.

    It specifies in particular:

    > the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;

    > the design and verification rules, constituting a benchmark for product certification.

    All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.


    Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.

    A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.

    Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.

    What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.

    [Schneider Electric]

    НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.

    Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.

    Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).

    В частности, он определяет:

    > распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;

    > конструкцию, технические характеристики, виды и методы испытаний НКУ.

    В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.

    Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.

    Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.

    Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.

    Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.

    [Перевод Интент]

     

    LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.

    The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.

    In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.

    Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.

    The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.

    [ABB]

    Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.

    Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам

    Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.

    Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются

    Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Действия

    Синонимы

    Сопутствующие термины

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte

    FR

    Русско-английский словарь нормативно-технической терминологии > НКУ распределения и управления

  • 3 правила техники безопасности при эксплуатации электроустановок потребителей

    Универсальный русско-английский словарь > правила техники безопасности при эксплуатации электроустановок потребителей

  • 4 система электрического питания для систем безопасности

    1. electric supply system for safety services

     

    система электрического питания для систем безопасности
    Система питания, предназначенная для поддержания работы электрического оборудования и электрических установок, необходимых:
    - для обеспечения здоровья и безопасности людей и(или) животных;
    - для предотвращения нанесения ущерба окружающей среде и другому оборудованию в соответствии с национальными правилами.
    Примечание - Система питания включает в себя источник питания и электрические цепи вплоть до зажимов электрического оборудования. В определенных случаях она может включать в себя также электрооборудование.
    [ ГОСТ Р МЭК 60050-826-2009]

    Наличие систем безопасности часто является установленным законом требованием для общественных зданий, очень высоких зданий и некоторых производственных зданий
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    electric supply system for safety services
    supply system intended to maintain the operation of essential electrical installation and equipment:
    – for the health and safety of persons and livestock, and/or
    – if required by national regulations, to avoid damage to the environment and to other equipment
    NOTE – The supply system includes the source and the electric circuits up to the terminals of electric equipment. In certain cases it may also include the equipment.
    [IEV number 826-10-04]

    FR

    système d'alimentation électrique pour installations de sécurité, m
    système d'alimentation prévu pour maintenir le fonctionnement de matériels et d'installations électriques essentiels:
    – pour la santé et la sécurité des personnes et des animaux domestiques, et/ou
    – pour éviter des dégâts à l'environnement et à d'autres matériels, si cela est exigé par les réglementations nationales
    NOTE – Le système d'alimentation inclut la source et les circuits électriques jusqu'aux bornes des matériels électriques. Dans certains cas, il peut aussi inclure ces matériels.
    [IEV number 826-10-04]

    Тематики

    EN

    DE

    • elektrische Anlage für Sicherheitszwecke, f

    FR

    • système d'alimentation électrique pour installations de sécurité, m

    Русско-английский словарь нормативно-технической терминологии > система электрического питания для систем безопасности

  • 5 тонкостенная металлическая труба для электропроводки

    1. intermediate metal conduit
    2. IMC
    3. EMT
    4. electrical metallic tubing

     

    тонкостенная металлическая труба для электропроводки
    -

    EN

    electrical metallic tubing
    A thin-walled metal raceway having a circular cross section; used to pull in or withdraw electric cables or wires after the tubing is installed in place; uses connectors and couplings other than the threaded type.
    [ http://www.answers.com/topic/electrical-metallic-tubing-1]

    intermediate metal conduit
    IMC

    -

    Intermediate metal conduit, or IMC for short, is a rigid steel electrical conduit that is lighter in weight than another rigid conduit. It was designed specifically to protect insulated electrical conductors and cables. It does the work of a similar conduit, galvanized rigid conduit (GRC), but with much less weight and thickness size. By utilizing IMC in areas allowed, you can all but eliminate the need for a heavier wall conduit.

    IMC has other advantages over GRC. It has a larger interior diameter than Galvanized Rigid Conduit and the smoother interior of the pipe allows for easier wire pulling through the conduit.

    IMC was originally introduced by Allied Tube & Conduit Corporation. It is manufactured in accordance with Underwriters’ Laboratories safety standard 1242 and ANSI C80.6. Believe it or not, Allied claims that IMC is actually more rigid than GRC in applications such as service masts and other installations. It has been installed in industrial and commercial buildings. In fact, the National Electrical Code has a specific article about IMC, article 342.

    IMC conduit is coated in a hot galvanized coating on the exterior and a special corrosive-resistant coating on the inside to extend the conduit’s lifespan for reliability. Common conduit sizes range from ½” to 4”.

    [ http://electrical.about.com/od/metalpvcconduit/a/IMCconduit.htm]

    Тематики

    • электропроводка, электромонтаж

    EN

    Русско-английский словарь нормативно-технической терминологии > тонкостенная металлическая труба для электропроводки

См. также в других словарях:

  • Electrical wiring — in general refers to insulated conductors used to carry electricity, and associated devices. This article describes general aspects of electrical wiring as used to provide power in buildings and structures, commonly referred to as building wiring …   Wikipedia

  • Electrical wiring (United States) — Electrical wiring in general refers to conductors used to carry electricity and their accessories. General aspects of electrical wiring as used to provide power in or to buildings and structures, commonly referred to as building wiring, are… …   Wikipedia

  • Electrical bonding — is the practice of intentionally electrically connecting all metallic non current carrying items in a room or building as protection from electric shock. If a failure of electrical insulation occurs, all metal objects in the room will have the… …   Wikipedia

  • Electrical wiring (UK) — The modern UK standards and regulations for electrical wiring no longer differ substantially from those in other European countries. However, there are a number of noteworthy national peculiarities, habits and traditions associated with domestic… …   Wikipedia

  • Electrical wiring in Hong Kong — This article exists to give readers an insight into electrical wiring in Hong Kong. Contents 1 Overview 2 Case specific analysis 2.1 Mainland China two pin plugs 2.2 …   Wikipedia

  • Canadian Electrical Code — The Canadian Electrical Code, CE code, or CSA C22.1 code is a standard published by the Canadian Standards Association for addressing electrical safety, shock, and fire hazards of electrical products in Canada. The Council for the Harmonization… …   Wikipedia

  • Safety — is the state of being safe (from French sauf ), the condition of being protected against physical, social, spiritual, financial, political, emotional, occupational, psychological, educational or other types or consequences of failure, damage,… …   Wikipedia

  • Electrical substation — An electrical substation is a subsidiary station of an electricity generation, transmission and distribution system where voltage is transformed from high to low or the reverse using transformers. Electric power may flow through several… …   Wikipedia

  • Oil Industry Safety Directorate — The Oil Industry Safety Directorate (OISD) is an organisation supported by all petroleum companies of India, like IOCL, ONGC, BPCL, HPCL, OIL etc. OISD has basically framed rules and guidelines for Safe Distances to be observed for various… …   Wikipedia

  • National Electrical Code — The National Electrical Code, 2008 edition The National Electrical Code (NEC), or NFPA 70, is a regionally adoptable standard for the safe installation of electrical wiring and equipment. The NEC, while having no legally binding regulation as… …   Wikipedia

  • Workplace (Health, Safety and Welfare) Regulations 1992 — Infobox UK Statutory Instrument Title=The Workplace (Health, Safety and Welfare) Regulations 1992 parliament=United Kingdom Parliament Citation=1992 No. 3004 introduced by=Patrick McLoughlin Department of Employment territorial extent=United… …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»